Yes, 110% or higher of rated output voltage (90 W), 130% or higher of rated output voltage (120 W), power shut off (shut off the input voltage and turn on the input again.
Series operation
Yes (For up to two Power Supplies, external diodes are required.)
Parallel operation
Yes (For up to two Power Supplies).
Output indicator
Yes (LED: Green)
Alarm indicator
Yes (LED: Red)
Indication monitor
Measurement and display details
Refer to datasheet.
Main display
7-segment LED (White)
None
7-segment LED (White)
None
Ethernet communication
Measurement and display details
Refer to datasheet.
Communication protocol
EtherNet/IP, Modbus TCP
Physical layer
100BASE-TX
Communication specifications
Refer to datasheet.
Insulation
Withstand voltage
3.0 kVAC for 1 min. (between all input terminals and output terminals, all EtherNet/IP ports), current cutoff 20 mA
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 30 mA
0.5 kVAC for 1 min. (between all output terminals and all EtherNet/IP ports), current cutoff 30 mA
Insulation resistance
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
100 MΩ min. (between all EtherNet/IP ports and all input terminals) at 500 VDC
Environment
Ambient operating temperature
−40 to 70°C (Derating is required according to the temperature.) (with no condensation or icing)
Storage temperature
−40 to 85°C (with no condensation or icing)
Ambient operating humidity
95% max. (Storage humidity: 95% max.)
Vibration resistance
10 to 55 Hz, maximum 5 G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability
MTBF
110,000 hrs typ.
150,000 hrs typ.
110,000 hrs typ.
140,000 hrs typ.
Life expectancy
10 years min.
Construction
Weight
350 g max.
400 g max.
Cooling fan
No
Degree of protection
IP20 by EN/IEC 60529
Note: For further information please refer to datasheet.
Power rating
240 W
480 W
Rated output voltage
24 V
24 V
Indication monitor
Included
None
Included
None
Efficiency
115 VAC input
91% typ.
91% typ.
92% typ.
92% typ.
230 VAC input
93% typ.
93% typ.
94% typ.
94% typ.
Input conditions
Voltage range
Single-phase, 85 to 264 VAC, 90 to 350 VDC, 265 to 300 VAC (1 second)
Yes, 130% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again).
Series operation
Yes (For up to two Power Supplies; external diodes required.)
Parallel operation
Yes (For up to two Power Supplies)
Output indicator
Yes (LED: Green)
Alarm indicator
Yes (LED: Red)
Indication monitor
Measurement and display details
Refer to datasheet.
Main display
7-segment LED (White)
None
7-segment LED (White)
None
Ethernet communication
Measurement and display details
Refer to datasheet.
Communication protocol
EtherNet/IP, Modbus TCP
Physical layer
100BASE-TX
Communication specifications
Refer to datasheet.
Insulation
Withstand voltage
3.0 kVAC for 1 min. (between all input terminals and output terminals, all EtherNet/IP ports),
2.0 kVAC for 1 min. (between all input terminals and PE terminals), current cutoff 20 mA
1.0 kVAC for 1 min. (between all output terminals and PE terminals), current cutoff 30 mA
0.5 kVAC for 1 min. (between all output terminals and all EtherNet/IP ports), current cutoff 30 mA
Insulation resistance
100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
100 MΩ min. (between all EtherNet/IP ports and all input terminals) at 500 VDC
Environment
Ambient operating temperature
−40 to 70°C (Derating is required according to the temperature.) (with no condensation or icing)
Storage temperature
−40 to 85°C (with no condensation or icing)
Ambient operating humidity
95% max. (Storage humidity: 95% max.)
Vibration resistance
10 to 55 Hz, maximum 5 G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions
Shock resistance
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Reliability
MTBF
100,000 hrs typ.
130,000 hrs typ.
90,000 hrs typ.
120,000 hrs typ.
Life expectancy
10 years min.
Construction
Weight
700 g max.
1,100 g max.
Cooling fan
No
Degree of protection
IP20 by EN/IEC 60529
Note: For further information please refer to datasheet.
Standards
Standards
Harmonic current emissions
Conforms to EN 61000-3-2
EMI
Conducted emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
Radiated emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B
EMS
Conforms to EN 61204-3 high severity levels
Safety standards
UL 508, ANSI/ISA 12.12.01 (Listing) (For 30 W, 60 W, and 90 W only Class 2 Output: Per UL 1310)
CSA C22.2 No. 107.1, CSA C22.2 No. 213 (cUL) (For 30 W, 60 W, and 90 W only Class 2 Output: Per CSA C22.2 No. 223)
UL 60950-1, UL 62368-1 (Recognition) OVC II ( ≤ 3000 m) Pol2 (For 30 W, 60 W, and 90 W only LPS)
CSA C22.2 No. 60950-1, No. 62368-1 (cUR) OVC II ( ≤ 3000 m) Pol2 (For 30 W, 60 W, and 90 W only LPS)
EN 50178 OVC III ( ≤ 2000 m) OVC II (2000 m < and ≤ 3000 m) Pol2
EN 60950-1, EN 62368-1 OVC II ( ≤ 3000 m) Pol2 (For 30 W, 60 W, and 90 W only LPS)
EAC (TR CU 004 / 2011, TR CU 020 / 2011)
RCM (EN61000-6-4)
Korea Radio Waves Act (Law No. 10564)
Conforms to PELV (EN/IEC 60204-1)
Conforms to EN/IEC 61558-2-16
SEMI
Conforms to F47-0706 (200 to 240 VAC input)
Note • EMI (radiated emissions) conform to Class B when this Power Supply is installed in a control panel.
• EN/IEC 61558-2-16 The S8VK-X was designed based on EN/IEC 61558-2-16. Currently, IEC 61558-2-17 has been replaced by IEC 61558-2-16. When certification was received for EN/IEC 60204-1 (Machinery Safety), it was necessary to go through a control transformer to the control circuits. However, a control transformer is not always necessary for product that have been certified for the safety standard for OVCIII or for product that use a transformer that conforms to EN/IEC 61558-2-16.
• Safety Standards for a DC Input When DC is used, UL 60950-1, UL 62368-1, cUR (CSA 22.2 No. 60950-1), cUR (CSA C22.2 No. 62368-1), EN/IEC 60950-1, EN/IEC 62368-1, EN 50178 and EN/IEC 61558-2-16 are applicable to safety standards. Safety standard compliance is achievable by connecting a UL-certified fuse as specified below. Select an external fuse that satisfies the following conditions: S8VK-X03005-EIP, S8VK-X06012-EIP, S8VK-X06024-EIP (350 VDC or more, 6 A) S8VK-X09024⬜-EIP, S8VK-X12024⬜-EIP, S8VK-X24024⬜-EIP (350 VDC or more, 8 A) S8VK-X48024⬜-EIP (350 VDC or more, 12 A)
• To comply with PELV output requirements for EN/IEC 60204-1, ground the negative side of the output (-V) to a protective earth (PE).
When the S8VK-R is used with switching power supplies, it provides a backup system for critical applications that require absolute reliability and zero downtime.
Prevents equipment stoppage, data loss and other problems resulting from momentary power failures. One S8T-DCBU-02 buffer block provides a back-up time of 500 ms at an output current of 2.5 A. Can be wired to the 24 VDC output from any switch mode power supply.
The S8M turns your machine directly into UL Class 2 compliant, maximum tripping current is 3,8A per channel (adjustable). This unit controls up to 4 circuits. On top of this you will get startup / shutdown –sequence control, display and alarm functions, like voltage, output current, runtime, and over temperature and external reset. These functions can be set by using the front buttons or with the free support tool software. These settings can be protected.