Ordering information
Rated voltage | Rated current | Order code |
---|
250 VAC 250 VDC | 3 A | S8V-NFS203 |
6 A | S8V-NFS206 |
Note: For details on normal stock models, contact your nearest OMRON representative.
Specifications
Item | Rated current | 3 A | 6 A |
---|
Rated voltage | Single-phase 250 VAC 50/60 Hz , 250 VDC |
---|
I/O characteristics | Leakage current | 1.0 mA max. (250 VAC/60 Hz) |
DC resistance | 110 mΩ max. |
Attenuation | 25 dB min. (Common Mode: 0.1 to 10 MHz, Normal Mode: 0.2 to 30 MHz) |
Withstand voltage | 2.5 kVAC for 1 min. (between line and ground), current cutoff 10 mA |
Insulation resistance | 100 MΩ min. (500 VDC, 1 min.) |
Environment | Ambient operating temperature | −40 to 85 °C (Derating is required.) (with no condensation or icing) |
Derating start temperature | +85°C | +60°C |
Storage temperature | −40 to 85°C (with no condensation or icing) |
Ambient operating humidity | 95% (Storage humidity: 95% max.) |
Vibration resistance | 10 to 55 Hz, maximum 5 G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions |
Shock resistance | 150 m/s², 3 times each in ±X, ±Y, ±Z directions |
Construction | Weight | 140 g max. |
Degree of protection | IP20 by EN/IEC 60529 |
Standards | Safety standards | UL 60939 (Recognition) OVC III ( ≤ 3000 m ) Pol2 CSA C22.2 No.8 EN 60939 OVC III ( ≤ 3000 m) Pol2 ENEC EAC (TR CU 004 / 2011) |